Single Point Loadcell ZEMIC H6F ZEMIC LOAD CELL SINGLE POINT TYPE H6F CAP 750KG-2T MERK : ZEMIC MODEL : ZEMIC LOAD CELL SINGLE POINT CAPACITY : 750KG - 2T MADE…
Single Point Loadcell ZEMIC H6F
ZEMIC LOAD CELL SINGLE POINT TYPE H6F CAP 750KG-2T
MERK : ZEMIC
MODEL : ZEMIC LOAD CELL SINGLE POINT
CAPACITY : 750KG - 2T
MADE IN : CHINA
Accuracy Class C3
Output Sensitivity ( = FS ) mV/V 2.0 ± 0.2*
Maximum Capacity ( Emax ) kg 100, 150, 200, 250, 350, 500, 750, 1000, 2000
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / vmin 10000
Combined Error %FS ≤± 0.023
Creep Error (30 minutes) %FS ≤± 0.020
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.017
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.014
Zero Balance %FS ≤± 1.5
Safe Overload %FS 150
Ultimate Overload %FS 300
Eccentric Loading Error %Ld/cm ± 0.002
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 384 ± 4
Output Resistance Ω 350 ± 2
Insulation Resistance (50V) MΩ ≥5000
Compensated Temperature °C -10 ~ + 40
Operating Temperature °C -35 ~ + 65
Load Cell Weight kg 100kg – 500kg: ~4.8 750kg – 2t: ~9.5 – 10.4
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP66
Recommended Torque on Fixation Bolts Nm M12: 75 M16: 160
ATEX Classification (optional) II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc