Compression Loadcell FLINTEC RC3 Merk : Flintec Model : RC3 Capacity : 30t Available models - RC3 / RC3-TS* Accuracy class according to OIML R60 - (GP) C3 C3 C3 MI7 C4 Available maximum capacities (Emax)…
Compression Loadcell FLINTEC RC3
Merk : Flintec
Model : RC3
Capacity : 30t
Available models - RC3 / RC3-TS*
Accuracy class according to OIML R60 - (GP) C3 C3 C3 MI7 C4
Available maximum capacities (Emax) t
7.5 / 15 /
22.5 / 30 /
40 / 50 /
100 / 150 /
300
7.5 / 15 /
22.5 30 / 40 / 50 30 / 40 / 50 30 / 40 / 50
Maximum number of verification intervals
(nLC) - n.a. 3500 3000 3000 4000
Minimum load cell verification interval (vmin) - n.a. Emax / 10000 Emax / 15000 Emax / 15000 Emax / 15000
Temp. effect on minimum dead load output
(TC0) %*RO/10°C ± 0.0400 ± 0.014 ± 0.0093 ± 0.0093 ± 0.0093
Temperature effect on sensitivity (TCRO)** %*RO/10°C ± 0.0200 ± 0.01 ± 0.01 ± 0.01 ± 0.008
Combined error*** %*RO ± 0.0500 ± 0.02 ± 0.02 ± 0.018 ± 0.018
Non-linearity** %*RO ± 0.0400 ± 0.0166 ± 0.0166 ± 0.0166 ± 0.0125
Hysteresis** %*RO ± 0.0400 ± 0.0166 ± 0.0166 ± 0.010 ± 0.0125
Creep error (30 minutes) / DR %*RO ± 0.0600 ± 0.0166 ± 0.0166 ± 0.0070 ± 0.0125
Minimum dead load (Emin) 0%*Emax
Rated Output (RO) mV/V 2 ± 0.1%
Calibration in mV/V/Ω (A...I classified) % ± 0.05 (± 0.005)
Zero balance %*RO ± 5
Excitation voltage V 5...15
Input resistance (RLC) 1,150 ± 50
Output resistance (Rout) 1,000 ± 2
Insulation resistance (100 V DC) M ≥ 5,000
Safe load limit (El
im) %*Emax 200
Ultimate load %*Emax 300
Compensated temperature range °C –10...+40
Operating temperature range °C –40...+80 (ATEX –40...+60)
Load cell material stainless steel 17-4 PH (1.4548)
Sealing complete hermetic sealing; cable entry sealed by glass to metal header
Protection according EN 60 529 IP68 (up to 2m water depth) / IP69K
Packet weight kg 1.3 (7.5t), 1.4 (15t), 1.5 (22.5t), 3.4 (30t), 3.6 (40t), 4.5 (50t), 12.9 (100t), 17.1
(150t), 32.8 (300t)
*The RC3-TS model is availabel in 30t and 40t at C3 or C3 MI7 accuracy, and is specifically intended for truck scales.
**The limits for Non-Linearity, Hysteresis, and TCRO are typical values.
*** The combined error meets the requirements of OIML R60 with pLC=0.7